Parameters of WPU-5(6)

0_wpu5_6s.jpg

Power of alternator, nominal 5 kW
Output voltage 48 VDC
Output voltage of inverter (quasi-sinusoid) 220/110 VAC
Nominal current frequency 50/60 Hz
  
Starting wind speed 3.5 m/s
Operating range of wind speed 4.. .60 m/s
Operation frequency 60-160 RPM
Nominal rotation frequency (wind 10.4 m/sec) 160 RPM
  
Number of air foils
6
Chord of air foil (length of horizontal cross-section) 460 mm
Diameter of wind rotor 5.1 m
Height of wind rotor 4.0 m
Swept area 20.4 sq.m
Height of mast 8-20 m
  
Vibration (acceleration amplitude, m/s2) in resonance
Noise, dBA (maximum acoustic level on maximum speed)
Infrasound, dB (level of acoustic pressure in octave range)
Ultrasound, dB
Electromagnetic radiation
- magnetic induction, 50Hz, mkTl
- electric field, kV/m
0.000043 m/s2
43 dBA
not detected
not detected

not measured
not measured
  
Range of operating temperature -50. . . +40 0C
Life time of power modules > 20 years
Time between servicing > 5 years
  
Mass of Wind Turbine, including:

      1. Rotor, including:
            1.1. Blades
            1.2. Hub
            1.3. Alternator
            1.4. Aerodynamic brake
            1.5. Mechanical brake (option)
            1.6. Support, bracing
       2. Mast
732 kg

472
kg
  89 kg
135 kg
  76 kg
  58 kg
    9 kg
105 kg
260 kg














































POWER versus WIND SPEED (inc. electrical efficiency)


WIND SPEED, m/sec  3 4 5 6 7 8 9 10 11 12
INSTANT POWER, kWatt (kW) 0.15 0.3 0.5 0.9 1.5 2.3
3.3
4.5 5.5 5.7
DAILY ENERGY, kW-hour  3.6 7.2
12
21.6
36 55.2
79.2 108
132 136.8
MONTHLY ENERGY, kW-hour
 108  216 360
648
1080
1656 2376
3240
3960 4104
ANNUAL ENERGY, kW-hour  1296 2592
4320
7776
12960
19872 28512 38880
47520
49248

Diagram of WPU-5(6) Power versus wind speed

farm05.jpg